Temporary Warehouse Features

Width: 32', 50', 66', or 82'(click dimension to see corresponding graphic)
Length: Unlimited [in 16' (5m) increments]
Eave Height: 15' Standard;  18' and 21' optional
Non Insulated: Single ply 26 gauge painted steel
or
Single ply 21 ounce vinyl coated fabric - flame retardant
Insulated: Double ply foam insulated 26 gauge painted steel
or
Double ply 21 ounce vinyl coated fabric - flame retardant - air insulated

Optional Building Equipment

  • Steel Overhead doors 15' wide (14', 16', 18' tall)
  • Steel Personnel doors
  • Wind Bracing

Safety and Security

  • Snow and wind load rated
  • Fully engineered
  • Expandable
  • Certified Flame retardant vinyl

Finance Plans

  • Lease (6 month minimum)
  • Purchase
  • Purchase/Buyback

Structure

Frame:
6061T Aluminum box beam extrusions.
252mm x 122mm for 32' and 50' wide structures.
334mm x 122mm for 66' and 82' wide structures.


Standard eave (lowest point) height = 15'.
18' and 21' eave heights available on 66' and 82' wide structures.

Roof Pitch = 18 degrees on all structures

Frame spacing = 5m (16'3")

No internal supports. Interior space is clear span.

Frame Connections: Galvanized steel inserts (50 ksi minimum) at all joints of rafters and eave uprights. Rafters and uprights are bolted with galvanized 3/4" (20mm) bolts.

Purlins: Eave, ridge, and internal roof areas - galvanized steel square tubing in 16' lengths provides bracing to the structural elements.

Cables: Roof and eave cables located in the first 5m and last 5m bays at a minimum. Structures exceeding 150' in length will have additional cabling.

Walls: Insulated wall system with 26-gauge steel inner and outer layers. Insulating 2" thick foam core. 36" x 15' 11" panels tongue-and-groove together and are stacked vertically to achieve desired eave height. R-Value - 17.2.

Non-insulated wall system with 2" thick, hollow core, steel reinforced, extruded PVC. 10" X 15' 11" panels are stacked vertically to achieve the desired height. Hollow core provides some dead air space insulation.

Roof Fabric: Air-inflated double layer of 20 oz/sq. yd. PVC coated polyester with 300 pli minimum tensile strength. Flame-retardant fabric meets fire codes. R-Value - 4 (estimated). Allows sunlight into the interior space. Requires a 110V, 20 amp outlet for air pump operations.

Wind Load: 90 mph Zone C exposure with Standard Importance Factor of 1.00 (20 psf at 100' height).

Snow Load: 15 psf (about 24" of snow at 13% density) snow-load support cables are placed every 5m, spanning eave to eave to prevent structural deflection under loading.

Doors: Overhead - chain-hoist-operated, single-ply steel sheeting roll-up doors. 14' height is standard. Widths in 15' 7" or 16', depending on placement in the structure perimeter.
  • Optional motorized and/or wind lock overhead doors available.
  • Personnel - 3' x 6' 8", insulated, 20-gauge steel, hollow-core doors with lever handles. Non-locking.
  • Surface

    Structure can be erected on solid dirt, asphalt, or existing concrete. Base plates under each eave and gable upright are anchored to the surface by 3' long steel stakes or 5/8" concrete anchor bolts. Slight terrain variances can be accommodated. Note: water can seep under walls if the interior ground level is lower than the exterior.

    Service

    TWS provides a straight, vertical-walled, steel-clad, clear-span structure with a commercial/industrial grade vinyl roof and gable panels. All materials are designed and engineered for long term use. Components bolt together for easy assembly and dismantling. The same structure can be used, relocated, and reerected repeatedly. Due to our modular-framework design, a structure can be lengthened or shortened from one job site to the next. Large square-footage requirements can be met by placing structure in a side-by-side configuration with no internal walls. A fabric gutter system between the abutted structures prevents almost all water from entering the structure. Our unique air-inflated roof panels add strength, eliminate condensation, eliminate fabric wind flutter, aid in shedding rain and snow, and add a dead-air-space insulation factor.

    TWS will deliver, install, and dismantle our structure at your site. We are confident that our product and service will exceed your expectations.

    Choose the option that best suits your needs.

    Call Us Today
    281-489-7811

    P.O. Box 540817
    Houston, TX 77254
    281-489-7811
    Fax: 281-489-6629
    Email Us